<dfn id="ucwie"></dfn>
<ul id="ucwie"><dfn id="ucwie"></dfn></ul>
<cite id="ucwie"><table id="ucwie"></table></cite>
<abbr id="ucwie"></abbr>
<cite id="ucwie"><table id="ucwie"></table></cite>
  • <fieldset id="ucwie"></fieldset>
  • Eng | 簡(jiǎn)體 | 繁體
    My favorites
    -> -> -> - >
    [Article]The following message about high was posted by Alice Dai
    07/13/2020
    Visit:42 ,Today:1

    Application Of Metal High Voltage Connectors New Energy

    At present, in the mainstream market (passenger car market), more plastic-oriented connectors are selected. Due to the combination of light weight and low cost, the cost will be the decisive factor in the next two years, but it does not mean metal. There is no market for mental connectors. Metal connectors have four excellent advantages compared to plastics in the transmission of large currents:

    1.Excellent shielding performance
    2.Good heat dissipation capacity
    3.Strong environmental resistance
    4.Smaller installation interface size (plastic products of the same grade)

    vs
    Plastic Connectors Mental Connectors

    Excellent Shielding Performance
    With the development of new energy vehicles, more and more electrical functions are being accumulated, and the shielding performance requirements of the entire vehicle are becoming higher and higher. For high-voltage systems, the layout of the wiring harness can basically be designed reasonably and the coverage of the shielding layer of the cable of the high-voltage wire harness can generally exceed 85%. For the high-voltage connector of the connection point of this system, the shielding performance is very important. If the shielding is a point to consideration, then the shielding performance of the high-voltage connector is this very important point.

    For plastic-grade connectors, we usually use a metal shield to conduct 360 ° continuous shielding conduction. For metal connectors, it can be directly conducted through its own body and the risk is lower and the shielding resistance. It will also be smaller. According to the standard requirements of the Volkswagen system, the contact resistance of the shield connection is less than 10mΩ throughout the life cycle of the product. Now in the industry, the general requirement is less than 5mΩ. The shielding performance of the shield of the plastic connector itself. It has been done very well and more is to consider the impact in extreme cases and whether the continuity of shielding can be guaranteed.
    Cooling Capacity
    High-current connector conduction requires the connector itself to have very good heat dissipation capacity. For the connector, like protection and shielding, three points need to be considered, and its own temperature source also comes from these three areas, 1. Board end connection area 2. mating end 3. wire end crimping area; if these three areas are not handled well, it is easy to cause the temperature to be too high, causing the material to deform, etc . Because the conducted current is large, the higher temperature is certain. We require that the temperature rise of the connector is less than 50K, but in fact, the local temperature caused by the long-term high current is higher. If the plastic-grade material will also form a higher temperature cavity on the central axis of the terminal Area, because the thermal conductivity of plastic material is small, compared with metal, it is about 1/500 ~ 1/600 of metal, so this will lead to a long-term temperature of the connector cavity. Which will cause a series of risk problems. from In this regard, under the same cable specifications, the effect of three-point contact is not considered for the time being. Metal has a better heat dissipation capacity than plastic.

    Installation interface Size More Smaller
    Because of the lack of shielding, the width of the metal connector can be made smaller. The size of the plastic connector can be reduced by more than 10mm. In some small installation spaces, this size will cause very important. The optimization of this size is getting bigger and bigger.

     
    Last modified: 2020-07-13 11:24:30
    • Contact Infomations

      Open Directory - Electronics - > Terminal - Application of Metal High Voltage Connectors New Energy

      Full Name: Alice Dai
      Email: alice@crmseo.com
      Mobile: N/A
      Company: N/A
      Telephone: N/A
      Address: N/A
      Postcode: N/A
      Website:
      Period of validity:N/A
    • Report this Ad - Welcome to Make a Pubilc Comment : Application Of Metal High Voltage Connectors New Energy

      * Required information

      Excellent Wrong Category Prohibited Contents Spam Outdated Other

      Full Name: *
      Message: *
      Telephone:
      Address:
      Postcode:
      Email:
      Website:
      Password:*
      * You can modify the message with it.
      Passcode:*
      passcode

    Related seek: Electronics Agents - Optical Instrument Parts - Capacitor - Calculator - Radar & Vector Device - Electronics Stocks - Telecom Parts - Telecom Cables - Relay - Display Parts - Insulation Material - Electronics - Transformer - Electronics Projects - Mobile Phone Decorations - Related Products - Commercial Field - Cable & Wire - Inductance Organ - Interphones - Electronic Data Systems - Terminal - Voice over IP (VoIP) - Phone Cards - Network Communications - Others - Others - Resistor - Wireless Communication - Magnetic Materials

    ©2025 Sun Wukong
    主站蜘蛛池模板: 真实国产精品vr专区| 55夜色66夜色国产精品视频| 成人国产精品免费视频| 色婷婷久久久SWAG精品| 2021年精品国产福利在线| 麻豆aⅴ精品无码一区二区| 国产精品国产三级国产AⅤ| 动漫精品专区一区二区三区不卡| 中文字幕精品视频在线| 国产亚洲午夜高清国产拍精品| 国产精品久久久久久久久| 久久棈精品久久久久久噜噜| 亚洲午夜福利精品久久| 女人高潮内射99精品| 国产乱子伦精品无码专区| 亚洲国产精品成| 国产精品福利在线观看| 成人伊人精品色XXXX视频| 久久精品亚洲一区二区三区浴池| 亚欧无码精品无码有性视频| 久久精品中文字幕第23页| 国产精品欧美久久久久无广告 | 精品一区二区三区自拍图片区| 日本熟妇亚洲欧美精品区| 国产精品无码素人福利| 国产精品玖玖美女张开腿让男人桶爽免费看| 99精品视频在线观看免费| 国产suv精品一区二区33| 国产精品嫩草影院AV| 国产精品igao视频网网址| 精品亚洲A∨无码一区二区三区| 欧美亚洲色综久久精品国产| 蜜芽亚洲av无码精品色午夜| 热re99久久6国产精品免费| 精品亚洲A∨无码一区二区三区| 国产精品无码成人午夜电影| 国产精品VA在线观看无码不卡| 国产成人精品日本亚洲网站 | 日韩精品一区二区三区视频| 久久精品国产一区二区电影| 久久这里只有精品视频99|